TPCS=0x0, MD=000, CST=0
General PWM Timer Control Register
CST | Count Start 0 (0): Count operation is stopped 1 (1): Count operation is performed |
MD | Mode Select 0 (000): Saw-wave PWM mode (single buffer or double buffer possible) 1 (001): Saw-wave one-shot pulse mode (fixed buffer operation) 2 (010): Setting prohibited 3 (011): Setting prohibited 4 (100): Triangle-wave PWM mode 1 (32-bit transfer at trough) (single buffer or double buffer is possible) 5 (101): Triangle-wave PWM mode 2 (32-bit transfer at crest and trough) (single buffer or double buffer is possible) 6 (110): Triangle-wave PWM mode 3 (64-bit transfer at trough) (fixed buffer operation) 7 (111): Setting prohibited |
TPCS | Timer Prescaler Select 0 (0x0): PCLKD/1 1 (0x1): PCLKD/2 2 (0x2): PCLKD/4 3 (0x3): PCLKD/8 4 (0x4): PCLKD/16 5 (0x5): PCLKD/32 6 (0x6): PCLKD/64 7 (0x7): Setting prohibited 8 (0x8): PCLKD/256 9 (0x9): Setting prohibited 10 (0xA): PCLKD/1024 11 (0xB): Setting prohibited 12 (0xC): GTETRGA (Via the POEG) 13 (0xD): GTETRGB (Via the POEG) 14 (0xE): GTETRGC (Via the POEG) 15 (0xF): GTETRGD (Via the POEG) |